Features
RDKP can be applied in the strong magnetic field environment such as automotive manufacturing or areas near welding machine.
When RDKP detects the magnetic AC field ( 50 or 60Hz ) it will keep the status of output and will not be effected.
Specifications
Wiring method | 2 wire |
---|---|
Switching logic | Solid state output,N.O. |
Switch type | Current sourcing |
Operating voltage | 10 ~ 28V DC |
Switching current | 5 ~ 50mA max. |
Switching rating | 1.5W max. (※1) |
Voltage drop | 5V max. |
Leakage current | 1mA max. |
Indicat | Unstable : Red LED ; Stable : Green LED |
Cable | φ5.4, 2C, PVC |
Temperature range | -10℃ ~ +60℃( No freezing ) |
Shock | 30G (※2) |
Vibration | 9G (※3) |
Enclosure classification | IEC 60529 IP67 |
Protection circuit | 3 , 4 (※4) |
Weight | 120g ( 3m Cable ) |
Remark | ※1 : Warning: Never exceed rating ( watt = voltage × amperage ). Permanent damage to sensor will occur. ※2 : Sin wave / X.Y.Z. 3 directions / 3 times each direction / 11ms each time. ※3 : Double amplitude 1.5mm / 10Hz~55Hz~10Hz(Sweep 1min) / X.Y.Z. 3 directions / 1 hour each time. ※4 : 1=None / 2=Short-circuit / 3=Power source reverse polarity / 4=Surge suppression. |